Sensor Electronics SEC 3100 Specifications

Browse online or download Specifications for Measuring, testing & control Sensor Electronics SEC 3100. Sensor Electronics SEC 3100 Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 13
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SEC MilleniumMillenium Carbon Dioxide
Gas Detector
Instruction and Operation Manual
Part Number 71-5000 Version 100201
Page view 0
1 2 3 4 5 6 ... 12 13

Summary of Contents

Page 1 - Gas Detector

SEC MilleniumMillenium Carbon Dioxide Gas Detector Instruction and Operation Manual Part Number 71-5000 Version 100201

Page 2

9 VI. Parts List Part Number Description 142-0617 Replacement Sensor SEC MILLENIUM (Specify range when ordering) 190-1001 SEC 2001 Sensor Sep

Page 3 - Table of Contents

10 VII. Drawing Section Figure # Title Figure 1 Wiring Diagram, SEC MILLENIUM Figure 2 SEC Sensor Separation Kit

Page 4 - I. SPECIFICATIONS

11 WIRING DIAGRAM MILLENIUM SENSOR FIGURE 1 WHITE: Calibration/Data RED: +24 VDC BLACK: -24VDC (DC Common) BLUE: 4 TO 20 mA Out OutOUTPUT 6.5

Page 5 - VDC (DC Voltage)

12 WIRE ENTRY FOR SENSOR 3/4 NPT WIRE ENTRY FOR RETURN TO SEC 3100 3/4 NPT NOTE: HOUSING RATED FOR CLASS 1, DIV 1, GROUPS B, C AND D SEC SENSO

Page 6

(SEC) designs and manufactures innovative fixed system gas detection equipment, for combustible gases, oxygen, carbon dioxide and toxic gases

Page 7 - III. OPERATION

Table of Contents I. SPECIFICATIONS II. GENERAL DESCRIPTION III. OPERATION Installation and Startup IV. CALIBRATION V. MAI

Page 8

3 I. SPECIFICATIONS Model: SEC MILLENIUM Infrared Carbon Dioxide (CO2) Gas Detector Part Number: 142-0617 Specify range when ordering Detect

Page 9 - V. MAINTENANCE

4 II GENERAL DESCRIPTION CONVENTIONS The following conventions are used in this manual. Warning Statement VDC (DC Voltage

Page 10 - VI. Parts List

5 Infrared Absorption Spectrum for Carbon Dioxide The dual channel receiver is a single wafer, double filtered, dual receiver with an intern

Page 11 - VII. Drawing Section

6 III. OPERATION Installation and Startup Warning: The user shall be made aware that if the equipment is used in a manner not specified by the m

Page 12 - FIGURE 1

7 Warm-up When power is applied to the detector, it enters a one (1) minute warm-up mode. The output current will be 0.8 mA during the warm up ti

Page 13 - FIGURE 2

8 IV. CALIBRATION SEC MILLENIUM The SEC MILLENIUM is factory calibrated zeroed and spanned. Unlike other types of sensors it does not requir

Comments to this Manuals